List of parameters
Parameter
1-569
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Assigns the individual cams to the maximum of 4 cam tracks and defines the numerical value for the SGA "cam
range".
p9538[0...29] = CBA dec
C = Assignment of the cam to the cam track.
Valid values are 1, 2, 3, 4.
BA = Numerical value for the SGA "cam range".
If the position lies in the range of this cam, the value BA is signaled to the safety-relevant logic via the SGA "cam
range" of the cam track set using C.
Valid values are 0 ... 14. Each numerical value may only be used once for each cam track.
Examples:
p9538[0] = 207
Cam 1 (index 0) is assigned cam track 2. If the position lies within the range of this cam, a value of 7 is entered in
the SGA "cam range" of the second cam track.
p9538[5] = 100
Cam 6 (index 5) is assigned cam track 1. If the position lies within the range of this cam, a value of 0 is entered in
the SGA "cam range" of the first cam track.
p9538[0...29]
SI Motion SCA cam track assignment (processor 1) / SI Mtn SCA assign.
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
100 414
[0]
100
[1] 101
[2] 102
[3] 103
[4] 104
[5] 105
[6] 106
[7] 107
[8] 108
[9] 109
[10] 110
[11] 111
[12] 112
[13] 113
[14] 114
[15] 200
[16] 201
[17] 202
[18] 203
[19] 204
[20] 205
[21] 206
[22] 207
[23] 208
[24] 209
[25] 210
[26] 211
[27] 212
[28] 213
[29] 214