Parameter
List of parameters
1-392
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the deceleration override for the traversing block.
The override refers to the maximum deceleration (p2573).
Dependency:
The number of indices depends on p2615.
Refer to: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623, p2624
Notice:
If, when calculating the traversing profile, it is identified that the target position of the next block with the pro-
grammed deceleration override will not be reached without direction reversal (flying block change), then the old
(current) deceleration override remains effective.
Description:
Sets the required task for the traversing block.
Value:
1:
POSITIONING
2:
FIXED STOP
3:
ENDLESS_POS
4:
ENDLESS_NEG
5:
WAITING
6:
GOTO
7:
SET_O
8:
RESET_O
9:
JERK
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2622, p2623, p2624
Description:
Sets additional information/data of the appropriate task for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2617, p2618, p2619, p2620, p2621, p2623, p2624
Note:
The following should be set depending on the task:
FIXED STOP: Clamping torque and clamping force (rotary 0...65536 [0.01 Nm], linear 0...65536 [N])
WAIT: Delay time [ms]
GOTO: Block number
SET_O: 1, 2 or 3 - set direct output 1, 2 or 3 (both)
p2620[0...n]
EPOS traversing deceleration override / Trav_block -a_over
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
p2615
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1.0 [%]
100.0 [%]
100.0 [%]
p2621[0...n]
EPOS traversing block task / Trav_block task
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
p2615
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 9
1
p2622[0...n]
EPOS traversing block task parameter / Trav_blck task_par
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
p2615
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-2147483648 2147483647
0