List of parameters
Parameter
1-455
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the recording cycle for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the recording time for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the trigger delay for the trace.
Trigger delay < 0:
Pretrigger: Tracing (recording) starts the selected time before the trigger event actually occurs.
Trigger delay > 0:
Post trigger: Tracing does not start until the set time after the trigger event.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Sets the time slice cycle in which the trace is called.
Index:
[0] = Trace 0
[1] = Trace 1
p4720[0...1]
Trace recording cycle / Trace record_cyc
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.000 [ms]
60000.000 [ms]
1.000 [ms]
p4721[0...1]
Trace recording time / Trace record_time
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.000 [ms]
3600000.000 [ms]
1000.000 [ms]
p4722[0...1]
Trace trigger delay / Trace trig_delay
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
-3600000.000 [ms]
3600000.000 [ms]
0.000 [ms]
p4723[0...1]
Time slice cycle for trace / Trace cycle
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0.03125 [ms]
4.00000 [ms]
0.12500 [ms]