
List of parameters
Parameter
1-519
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the mapping parameters for CANopen Transmit Process Data Object 8 (TPDO 8).
Index:
[0] = Mapped object 1
[1] = Mapped object 2
[2] = Mapped object 3
[3] = Mapped object 4
Note:
Corresponds to the CANopen object 1A07 hex + 40 hex * x (x: Drive number 0 ... 7).
The parameter can only be written online when the associated COB ID in p872x is set as invalid.
Description:
Acknowledges the setting of the Predefined Connection Sets (p8744).
Value:
0:
Inactive
1:
Acknowledge configuration
Dependency:
Refer to: p8744
Description:
Displays the drive ID associated with each drive.
Index:
[0] = Drive ID for 1st drive
[1] = Drive ID for 2nd drive
[2] = Drive ID for 3rd drive
[3] = Drive ID for 4th drive
[4] = Drive ID for 5th drive
[5] = Drive ID for 6th drive
[6] = Drive ID for 7th drive
[7] = Drive ID for 8th drive
Description:
Selector switch for the PDO mapping.
Sets the mapping for download or in the online mode after acknowledging with p8741.
p8737[0...3]
CAN Transmit Mapping for TPDO 8 / Mapping TPDO 8
SERVO_S110-CAN
Can be changed:
C1(3), T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
9208
P-Group:
Communications
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p8741
CAN PDO configuration acknowledgement / PDO config ackn
CU_S110-CAN
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
r8743[0...7]
CAN assignment drive/drive ID / Drive ID
CU_S110-CAN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p8744
CAN PDO mapping configuration / PDO Mapping conf.
SERVO_S110-CAN
Can be changed:
C2, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
-
Func. diagram:
9204, 9206,
9208, 9210
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 2
2