R01UH0336EJ0102 Rev.1.02
Page 866 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 15 TSG2 (TSG20)
Table 15-66
Example of Setting Each Timer Output Condition in SP-PWM Mode (2/2)
Pin
Item
Output Period
Output Duty
Output Condition
Setting Condition
TSG2nO2,
TSG2nO4,
TSG2nO6
PWM output
(T 1) × count
clock
Output an inactive level
throughout one period
(duty 0%)
TSnCMPm =
TSnCMP(m - 1) or
TSnCMP(m - 1) >
TSnCMP0 (m = 2, 6,
10)
Output an active level
of one count clock in
one period
TSnCMPm =
TSnCMP(m - 1) - 1
TSnCMP(m - 1) =
T 1 (m = 2,
6, 10)
Output an inactive level
of one count clock in
one period
TSnCMPm =
TSnCMP(m - 1) + 1
TSnCMP(m - 1) =
TSnCMPm - 1 (m = 2,
6, 10)
Output an active level
throughout one period
(duty 100%)
TSnCMPm >
TSnCMP0 (m = 2, 6,
10)
TSG2nO7
Diagnostic signal
output or pulse
output by A/D
conversion trigger
(T 1) × count
clock
Please refer to Section 15.9, A/D Conversion
Trigger Function.