R01UH0336EJ0102 Rev.1.02
Page 1205 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 21 Clocked Serial Interface G (CSIG)
(9)
CSIGnTX0H - CSIG Transmission Register 0 for Half Word Access
This register stores the transmission data. It can be used when the extended
data length function is disabled (CSIGnCTL1.CSIGnEDLE = 0).
Access
This register can be read/written in 16-bit units.
Address
<CSIGn_base1> + 88
H
Initial value
0000
H
This register is initialized by a reset from any source.
Caution
Writing to this register is forbidden when CSIGnCTL0.CSIGnTXE = 0 and
CSIGnCTL0.CSIGnRXE = 0.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CSIGnTX[15:0]
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Table 21-17
CSIGnTX0H Register Contents
Bit Position
Bit Name
Function
15 to 0
CSIGnTX
[15:0]
Data to be transmitted