R01UH0336EJ0102 Rev.1.02
Page 1013 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 19 Timer Option Module (TAPA)
Section 19 Timer Option Module (TAPA)
The timer option module is described in this section.
19.1 Features of the Timer Option Module
Instances
This product has the following number of instances of timer option modules.
Instances
index n
Throughout this section, the individual instances of the timer option function
are identified by the index “n” (n = 0, 2). For example, TAPAnFLG indicates the
TAPAn flag registers.
Register
addresses
All TAPAn register addresses are given as address offsets from the given base
address, <TAPAn_base0> or <TAPAn_base1>.
Each of the TAPAn base addresses is listed in the following table.
Clock supply
The following clock signal is input to the timer option.
Table 19-1
Instances of Timer Option Modules
Timer Option
Instances
2
Name
TAPAn
Table 19-2
Register Base Address
TAPAn
<TAPAn_base0> Address
<TAPAn_base1> Address
TAPA0
FF81 5000
H
FFFF D400
H
TAPA2
FF81 7000
H
FFFF D600
H
Table 19-3
TAPA Clock Supply
TAPAn
TAPAn Clock
Connected to
TAPA0
PCLK
Clock controller
TAPA2