(8)
LEDADR - On-chip RAM ECC Error Detection Address Register
When an ECC error is encountered in access to on-chip RAM, this register
holds the corresponding address. If LECCER.LECCER0EDFLG is 0, the
stored address where the error was encountered is not changed until clearing
of LECCER0EDFLG.
Access
This register can be read in 32-bit units.
Address
FF46 800C
H
Initial value
0000 0000
H
This register is initialized by clearing the LECCER.LECCER0EDFLG bit or by a
reset from any source.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
0
0
0
0
0
0
0
0
0
0
LEDADR0A[20:16]
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
LEDADR0A[15:2]
0
0
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Table 9-27
Contents of the On-chip RAM ECC Error Detection Address Register
Bit Position
Bit Name
Function
20 to 2
LEDADR0A
[20:2]
These bits hold the address where an ECC error was encountered in access
to on-chip RAM.