R01UH0336EJ0102 Rev.1.02
Page 290 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 8 Reset Controller
8.2.7
Self-Diagnostic BIST Reset
Self-diagnostic BIST is usually executed after release from any reset source
(except SWRES). This kind of reset is generated after self-diagnostic BIST to
initialize the circuits that are the target of self-diagnostic BIST.
The generation of BISTRES is indicated by RESF.RESF7.
RESF.RESF7 is not automatically cleared. It is cleared by
• setting RESFC.RESFC7 = 1
• SYSRES
8.2.8
Safety Guardian Reset
The safety guardian (SGA) collects all internal error signals from different
monitoring units.
All error inputs connected to the SGA are able to generate the SGARES reset
signal.
After a safety guardian reset, the safety guardian reset flag RESF.RESF6 is
set.
RESF.RESF6 is not automatically cleared. It is cleared by
• setting RESFC.RESFC6 = 1
• SYSRES