V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(c)
Channel output mode for master channels
TAUBnTOE.TAUBnTOEm is set to 0 because channel output mode is not used
with this function. However, this mode can be used with another function or in
independent channel output mode controlled by software.
(d)
Simultaneous rewrite for master channels
The simultaneous rewrite settings for master and slave channel should be
identical.
Table 13-92
Simultaneous Rewrite Settings for Master Channels of One-Shot Pulse
Output Function
Bit Name
Setting
TAUBnRDE.TAUBnRDEm
1: Enables simultaneous rewrite.
TAUBnRDS.TAUBnRDSm
0: Master channel is simultaneous rewrite control
channel.
TAUBnRDM.TAUBnRDMm
0: Generates a simultaneous rewrite trigger signal
when master channel starts to count.
TAUBnRDC.TAUBnRDCm
0: INTTAUBnIm signal used to trigger a
simultaneous rewrite is not monitored on the
channel. When TAUBnRDS.TAUBnRDSm = 0,
the master channel is monitored for simultaneous
rewrite triggers regardless of the value of this bit.