R01UH0336EJ0102 Rev.1.02
Page 784 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 15 TSG2 (TSG20)
(a)
Reload Rewrite Setting Example in Each Mode
Reloading conditions and setting examples are shown in Table 15-41 and
Table 15-42.
Table 15-41
List of Reload Settings (when TSnCTL3.TSnRIA = 0)
Mode
TSnCTL4.
TSnPRE
TSnCTL4.
TSnVRE
TSnCTL4.
TSnPIE
TSnCTL4.
TSnVIE
TSnCTL4.
TSnRCC4 to
TSnRCC0
Reload
PWM mode
0
0/1
0/1
0/1
Any value
Setting prohibited
SP-PWM mode
1
0
0/1
0/1
Any value
When INTTSG2nI00 is
generated.
120-DC mode
1
1
0/1
0/1
Any value
When INTTSG2nI00 is
generated.
HT-PWM mode
0
0
0/1
0/1
Any value
Setting prohibited
0
1
0/1
0/1
Any value
When INTTSG2nIVLY is
generated.
1
0
0/1
0/1
Any value
When INTTSG2nIPEK is
generated.
1
1
0/1
0/1
Any value
When INTTSG2nIPEK or
INTTSG2nIVLY is generated.
Table 15-42
List of Reload Settings (when TSnCTL3.TSnRIA = 1)
Mode
TSnCTL4.
TSnPRE
TSnCTL4.
TSnVRE
TSnCTL4.
TSnPIE
TSnCTL4.
TSnVIE
TSnCTL4.
TSnRCC4-
TSnRCC0
Reload
PWM mode
0
0/1
0/1
0/1
Any value
Setting prohibited
SP-PWM mode
1
0
0
0/1
Any value
Setting prohibited
120-DC mode
1
0
1
0/1
Any value
When INTTSG2nI00 is
generated.
1
1
0
0/1
Any value
Setting prohibited
1
1
1
0/1
Any value
When INTTSG2nI00 is
generated.
HT-PWM mode
0
0
0/1
0/1
Any value
Setting prohibited
0
1
0
0
Any value
Setting prohibited
0
1
0
1
Any value
When INTTSG2nIVLY is
generated.
0
1
1
0
Any value
Setting prohibited
0
1
1
1
Any value
When INTTSG2nIVLY is
generated.
1
0
0
0/1
Any value
Setting prohibited
1
0
1
0/1
Any value
When INTTSG2nIPEK is
generated.
1
1
0
0
Any value
Setting prohibited
1
1
0
1
Any value
When INTTSG2nIVLY is
generated.
1
1
1
0
Any value
When INTTSG2nIPEK is
generated.
1
1
1
1
Any value
When INTTSG2nIPEK or
INTTSG2nIVLY is generated.