V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(c)
Operation stop and restart
Figure 13-21
Operation Stop and Restart (TAUBnCMORm.TAUBnMD0 = 1)
• The counter can be stopped by setting TAUBnTT.TAUBnTTm to 1. This sets
TAUBnTE.TAUBnTEm to 0.
• TAUBnCNTm and TAUBnTTOUTm stop but retain their values.
• The counter can be restarted by setting TAUBnTS.TAUBnTSm to 1.
(d)
Forced restart
Figure 13-22
Forced Restart Operation (TAUBnCMORm.TAUBnMD0 = 1)
• The counter can be forcibly restarted (without stopping it first) by setting
TAUBnTS.TAUBnTSm to 1 during operation.
• If the TAUBnCMORm.TAUBnMD0 bit is set to 1, the first interrupt after a
start or restart is generated.