Section 27 Electrical Characteristics
27.6.7
ESOn Timing
(T
a
= -40 to +125°C, V
DD
= EV
DD
= OSCV
DD
= 3.0 to 5.5 V,
AV
DD0
= 4.2 to 5.5 V, V
SS
= EV
SS
= OSCV
SS
= AV
SS0
= 0 V)
Caution
The above values are for pulse widths that ensure detection of an effective
edge. An effective edge may also be detected even if the input pulse width is
less than the above specification.
Note
n = 0 or 2
Item
Symbol
Conditions
MIN.
MAX.
Unit
ESOn input high-level width
t
WESOH
Analog filter
500
ns
ESOn input low-level width
t
WESOL
Analog filter
500
ns
E SOn
t
W E S O H
t
W E S O L