R01UH0336EJ0102 Rev.1.02
Page 1087 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 20 CAN Controller (FCN)
(b)
FCNnCMTGTX Write
(14)
FCNnCMTSCTL - FCNn Module Time Stamp Register
This register is used to control the time stamp function.
Access
This register can be read/written in 16-bit units.
Address
<FCNn_base> + 0 8298
H
Initial value
0000
H
This register is initialized by various types of reset.
(a)
FCNnCMTSCTL Read
Note
The lock function of the time stamp function must not be used when the FCN
module is in normal operating mode with ABT.
Note 1. FCNnCMTSTSGE is automatically cleared to 0.
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
FCNnCM
TGCLTV
FCNnCMTGCLTV
Setting FCNnCMTGTVFF
0
FCNnCMTGTVFF bit is not changed.
1
FCNnCMTGTVFF bit is cleared to 0.
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
FCNnCM
TSLOKE
FCNnCM
TSSELE
FCNnCM
TSTSGE
FCNnCMTSLOKE
Time Stamp Lock Function Enable
0
Time stamp lock function stopped.
The TSOUT signal is toggled each time the selected
time stamp capture event occurs.
1
Time stamp lock function enabled.
The TSOUT signal is toggled each time the selected
time stamp capture event occurs.
However, the TSOUT output signal is locked when a
data frame has been correctly received to message
buffer 0.
*
1
FCNnCMTSSELE
Time Stamp Capture Event Selection
0
The time capture event is SOF.
1
The time stamp capture event is the last bit of EOF.