R01UH0336EJ0102 Rev.1.02
Page 374 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 10 Safety Guardian (SGA)
(15)
SGAPS - SGA Protection Status Register
This register is used to verify whether the write protected register has been
written successfully or not.
For details, refer to Section 10.3.7, Writing to Protected Registers.
Access
This register can be read in 32-bit units.
Address
<SGA_base> + 24
H
Initial value
0000 0000
H
This register is initialized by a reset from any source.
Table 10-25
SGAPS Register Contents
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
SGA
PRE
RR
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Bit position
Bit Name
Function
0
SGAPRERR
Indicates whether writing to a write protected register failed or was
successful.
0: Writing was successfully completed.
1: Writing failed.