R01UH0336EJ0102 Rev.1.02
Page 601 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
Note
If the operating mode is changed while the counter is stopped, the initial
counter value after a counter restart becomes undefined. The operating mode
is changed by the TAUBnCMORm.TAUBnMD[4:1] register.
Table 13-125
TAUBnCNTm Read Values after Re-Enabling Counter
Mode Name
Count Method
(Up/Down)
TAUBnCNTm Value
After Reset
After Stop Trigger
After One Count
Interval timer mode
Count down
FFFF
H
Stop value
-
Judge mode
Count down
FFFF
H
Stop value
-
Capture mode
Count up
0000
H
Stop value
-
Event count mode
Count dow
FFFF
H
Stop value
-
One-count mode
Count down
FFFF
H
Stop value
FFFF
H
Capture and one-count mode
Count up
0000
H
Stop value
Capture value + 1
(TAUBnCDRm)
Judge and one-count mode
Count down
FFFF
H
Stop value
TAUBnCNTm value
- 1
Up/down count mode
Count down/up
FFFF
H
Stop value
-
Pulse one count mode
Count down
FFFF
H
Stop value
0000
H
Count capture mode
Count up
0000
H
Stop value
-
Capture and gate count mode
Count up
0000
H
Stop value
Stop value