R01UH0336EJ0102 Rev.1.02
Page 536 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(7)
Operating procedure for delay pulse output function
Table 13-89
Operating Procedure for Delay Pulse Output Function (1/2)
Operation
TAUBn Status
Initial
Ch
ann
el
Settin
g
Master channels: Set TAUBnCMORm and
TAUBnCMURm registers and the channel
output mode as described in (3) Register
settings for master channels.
Slave channel 1: Set TAUBnCMORm and
TAUBnCMURm registers and the channel
output mode as described in (4) Register
settings for slave channel 1.
Slave channel 2: Set TAUBnCMORm and
TAUBnCMURm registers and the channel
output mode as described in (5) Register
settings for slave channel 2.
Slave channel 3: set the TAUBnCMORm and
TAUBnCMURm registers and the channel
output mode as described in (6) Register
settings for slave channel 3.
Set TAUBnCDRm register value of every
channel.
Channel operation is stopped.