R01UH0336EJ0102 Rev.1.02
Page 422 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
The various channel output modes and the channel output control bits are
listed in the following table.
• Any combinations not described in the above table are prohibited.
• The bit marked with "x" can be set to any value.
Note
The following bits cannot be changed during count operation
(TAUBnTE.TAUBnTEm = 1):
• TAUBnTOE.TAUBnTOEm
• TAUBnTOM.TAUBnTOMm
• TAUBnTOC.TAUBnTOCm
• TAUBnTDE.TAUBnTDEm
Table 13-10
Channel Output Modes
Channel Output Modes
TAUBn
TOE.
TAUBn
TOEm
TAUBn
TOM.
TAUBn
TOMm
TAUBn
TOC.
TAUBn
TOCm
TAUBn
TDE.
TAUBn
TDEm
By software
Independent channel output mode controlled
by software
0
X
By TAUB signals, independently
Independent channel output mode 1
1
0
0
0
Independent channel output mode 2
1
By TAUB signals, synchronously
Synchronous channel output mode 1
1
1
0
0
Synchronous channel output mode 2
1
with dead time output
1