V850E2/PG4-L
Section 15 TSG2 (TSG20)
(2)
Interrupt/Reload Skipping Function in PWM Mode
By setting TSnCTL4.TSnPRE and TSnPIE to 1 and setting the TSnRCC04 to
TSnRCC00 and TSnCTL3.TSnRIA, the reload and interrupt skipping function
can be used.
By setting TSnPRE to 1 and setting the TSnRCC04 to TSnRCC00, the
interrupt skipping function can be used.
(3)
Controlling Dead Time in PWM Mode
By setting the TSnDTC0 and TSnDTC1 registers in PWM mode, it is possible
to control the dead time. The dead time is controlled according to the switch
timing of the TSG2nO1 output, the TSG2nO2 output, the TSG2nO3 output, the
TSG2nO4 output, the TSG2nO5 output, and the TSG2nO6 output.
Table 15-54
Dead Time in PWM Mode
Switch Timing
Dead Time
TSG2nO1: High level to low level
TSG2nO2: Low level to high level
Value of TSnDTC1 register
TSG2nO2: High level to low level
TSG2nO1: Low level to high level
Value of TSnDTC0 register
TSG2nO3: High level to low level
TSG2nO4: Low level to high level
Value of TSnDTC1 register
TSG2nO4: High level to low level
TSG2nO3: Low level to high level
Value of TSnDTC0 register
TSG2nO5: High level to low level
TSG2nO6: Low level to high level
Value of TSnDTC1 register
TSG2nO6: High level to low level
TSG2nO5: Low level to high level
Value of TSnDTC0 register