
R01UH0336EJ0102 Rev.1.02
Page 442 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 13 Timer Array Unit B (TAUB)
(4)
Register settings
(a)
TAUBnCMORm
(b)
TAUBnCMURm
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TAUBnCKS
[1:0]
TAUBnCCS
[1:0]
TAUB
nMAS
TAUBnSTS[2:0]
TAUBnCOS
[1:0]
-
TAUBnMD[4:1]
TAUB
nMD0
Table 13-17
TAUBnCMORm Settings for TAUBnTTINm Input Interval Timer Function
Bit Name
Setting
TAUBnCKS[1:0]
00: Operation clock = CK0
01: Operation clock = CK1
10: Operation clock = CK2
11: Operation clock = CK3
TAUBnCCS[1:0]
00: Uses an operation clock as a count clock.
TAUBnMAS
0: Unused. Set to 0.
TAUBnSTS[2:0]
001: Valid TAUBnTTINm input edge signal is used as an
external start trigger.
TAUBnCOS[1:0]
00: Unused. Set to 00.
TAUBnMD[4:1]
0000: Interval timer mode
TAUBnMD0
0: INTTAUBnIm is not generated to toggle TAUBnTTOUTm at
the beginning of an operation.
1: INTTAUBnIm is generated to toggle TAUBnTTOUTm at the
beginning of an operation.
7
6
5
4
3
2
1
0
-
TAUBnTIS[1:0]
Table 13-18
TAUBnCMURm Settings for TAUBnTTINm Input Interval Timer Function
Bit Name
Setting
TAUBnTIS[1:0]
00: Falling edge detection
01: Rising edge detection
10: Rising and falling edge detection