4-130
4-11-6 Analog Monitor Output Adjustment
•
The following two types of analog monitor output adjustment can be performed using System Check
Mode.
•
Analog monitor output offset manual adjustment (Fn00C).
•
Analog monitor output scaling (Fn00d)
Note 1.
Set the monitor items to be output from the analog monitor using Pn003.0 (analog monitor 1
(AM) allocation), and Pn003.1 (analog monitor 2 (NM) allocation).
Note 2.
The maximum analog monitor output voltage is
±
8 V. Exceeding this value may result in an
abnormal output.
Note 3.
Analog monitor output accuracy is approximately
±
15%
H
Analog Monitor Output Offset Manual Adjustment (Fn00C)
•
Use this function to adjust the analog output monitor offset. You can adjust each of the two monitor
outputs separately.
•
The analog monitor output offset adjustment range is --128 to 127 (x 17 mV).
Note
When adjusting the analog monitor output offset, confirm that the output voltage is zero (e.g., if
outputting the Servomotor rotation speed, confirm that the servo is OFF and the Servomotor shaft
is not moving) before connecting the measuring instrument to be used.
System Check Mode
Analog monitor
output
Offset manual ad-
justment
Word selection (word 1)
Word selection (word 2)
Analog monitor 1 (AM)
offset adjustment
Analog monitor 2 (NM)
offset adjustment
1 s max.
1 s min.
1 s min.
1 s min.
1 s min.
1 s max.
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]