4-9
•
If a Parameter Unit is connected, the indicators (7-segment LEDs) on the front panel will flash, and
the settings keys cannot be used.
H
Keys and Functions
PR02W Front panel
keys
Function
Alarm reset
Mode switching
Data memory
Servo ON/OFF during jog op-
erations
Switching between parameter
display and data display; data
memory
Increments parameter numbers
and data values.
Decrements parameter num-
bers and data values.
Left shift for operation digits
Right shift for operation digits
H
Modes
OMNUC W-series AC Servo Drivers have the following four modes.
Mode
Function
Status Display
Mode
This mode displays the internal Servo Driver status using bit display (LED lit/not lit) and
symbol display (7-segment 3-digit LEDs).
Bit display: Control-circuit power supply ON display, main-circuit power supply ON dis-
play, baseblock, in position, speed conformity, rotation detection, command pulses be-
ing input, speed command being input, torque command being input, deviation counter
reset signal being input.
Symbol display: Baseblock (bb), operating (run), forward rotation prohibited (Pot), re-
verse rotation prohibited (not), alarm display (A.
jj
)
System Check
Mode
Alarm history display, rigidity setting during online auto-tuning, jog operation, Servomo-
tor origin search, user parameter initialization, alarm history data clear, online auto-tun-
ing results storage, absolute encoder setup, automatic command offset adjustment,
manual command offset adjustment, manual analog monitor output offset adjustment,
analog monitor output scaling, automatic Servomotor current detection offset adjust-
ment, manual current detection offset adjustment, password setting, Servomotor pa-
rameters check, version check, absolute encoder rotation setting change
Settings Mode
This is the mode for setting and checking user parameters (Pn
jjj
)
Monitor Mode
This mode monitors the I/O status for each signal and internal Servo Driver data.
Speed feedback, speed commands, torque commands, number of pulses from Z-
phase, electrical angle, internal signal monitor, external signal monitor, command pulse
speed display, position displacement, cumulative load rate, regeneration load rate, dy-
namic brake load rate, input pulse counter, feedback pulse counter
Parameter Unit
Servo Driver front panel
settings area
Operation
Chapter 4