6-5
H
Connection Example 4: Connecting to SYSMAC C500-NC222-E
Position Control Units
C500-NC222-E
0 V
MD Connector
Name
Signal
X axis + A-phase input
X axis -- A-phase input
X axis + B-phase input
X axis -- B-phase input
X axis + Z-phase input
X axis -- Z-phase input
X-axis speed command
X-axis speed cmnd., 0V
24 V for OUT output
X-axis OUT 2 output
Signal
R88D-WT
j
R88M-W
j
Encoder Cable
R88A-CRW
j
Power Cable
R88A-CAW
j
Red
White
Blue
Green/
Yellow
Class-3 ground
No
ise
filte
r
Main circuit power supply
200/230 V AC 50/60Hz
0 V
24 V DC
EXT IN Connector
Name
X-axis CCW limit input
X-axis extrnl. stop input
X-axis external servo free input
X-axis CW limit input
0 V
X-axis origin input
Frame ground
24 V for input
Main circuit contact
Surge killer
Shell
DC reactor
24 V DC
24 V DC
Note 1.
The example shows a -phase, 200-V AC input to the Servo Driver for the main circuit power
supply. Be sure to provide a power supply and wiring conforming to the power supply specifi-
cations for the Servo Driver in use.
Note 2.
Incorrect signal wiring can cause damage to Units and the Servo Driver.
Note 3.
Leave unused signal lines open and do not wire them.
Note 4.
The diode recommended for surge absorption is the ERB44-02 (Fuji Electric).
Note 5.
This wiring diagram is an example of X-axis wiring only. For two-axis control, the external in-
put and Driver wiring must be connected for the Y axis in the same way.
Note 6.
External output 2 (OUT-2X) can be turned ON and OFF with external servo-unlocked input, at
which time external output 2 of the C500-NC222-E’s address numbers 420 (X axis) and 820
(Y axis) must be set to 1 (turned OFF at the time of servo free).
Note 7.
When the C500-NC222-E is used in NC221 mode, external servo-unlocked input works as
emergency stop input. Therefore external output 2 cannot be used as a RUN signal. Input a
RUN signal from other I/O terminals.