4-103
Note 2.
A torque will be generated that accelerates the Servomotor in the forward direction if torque
feed-forward is applied with a positive (+) voltage. Be sure that the polarity is correct because
errors such as reverse Servomotor rotation or oscillation will occur if the feed-forward is ap-
plied with a polarity opposing the acceleration direction.
4-8-4
Speed Feed-forward Function (Position)
H
Functions
•
This function shortens positioning time by adding the REF (speed command input) value to the speed
loop.
•
Normally, the differential value for the position command (pulse train command) is generated in the
controller, and input to REF.
•
If the feed-forward amount (REF voltage) is too large, an overshoot may occur, so adjust Pn300
(speed command scale) as required.
Speed Feed-forward Function Block Diagram
Host Controller
Differ-
ential
Position command
Speed feed-forward
Command
pulses
Encoder output
Speed com-
mand scale
Electronic gear
ratio (G1/G2)
Encoder di-
viding rate
Deviation
counter
Speed
detection
Current
detection
Current
loop
Speed
loop
Servo Driver
H
Parameters Requiring Settings
Parameter No.
Parameter
name
Explanation
Example
Pn207.1
Speed command
input switching
Set Pn207.1 to 1 (use REF as speed torque
feed-forward input).
4-4-4 Parameter
Details
Pn300
Speed command
scale
Adjust the speed feed-forward amount. (See note.)
e a s
Note
The default setting is 1000 (x 0.01 V / rated number of revolutions).
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]