4-134
Note
Automatic adjustment can be performed only when the power supply to the main circuits is turned
ON, and the power supply to the servo is OFF.
System Check Mode
Servomotor current
detection offset automatic
adjustment
Offset automatic ad-
justment display
(“Cur_o” displayed)
Automatic adjustment com-
pleted (“donE” flashes)
Perform automatic ad-
justment
Return to
“Cur_o” display
(1 s later)
1 s min.
1 s min.
Operation Procedure
PR02W
operation
Front panel
key operation
Display
Explanation
Press the MODE/SET Key to change to System Check
Mode.
Press the Up or Down Key to set function code Fn00E.
(See note.)
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to display “Cur_o”.
Press the MODE/SET Key to perform automatic offset
adjustment. When automatic adjustment is completed,
“donE” will be displayed for approximately 1 s.
(Approx. 1 s later)
After “donE” has been displayed, the display will return
to “Cur_o.”
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to return to the System Check Mode function code
display.
Note
The digits you can manipulate will flash.
H
Servomotor Current Detection Offset Manual Adjustment (Fn00F)
•
This function manually adjusts the Servomotor current detection offset.
•
Adjust the U-phase and V-phase offsets alternately while balancing each separately.
•
When performing adjustments, rotate the Servomotor at 100 r/min. without connecting the mechani-
cal system to the Servomotor shaft (i.e., make sure there is no load), and perform the adjustments
while monitoring the waveform of the analog monitor output’s torque command monitor (current moni-
tor).
•
The Servomotor current detection offset setting range is --512 to 511.
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]