4-26
H
Sequence Parameters (From Pn500)
Para-
Parameter
Explanation (See note 1.)
Default
tti
Default
tti
Unit
Setting Restart
?
meter
No.
name
Digit
No.
Name
Set-
ting
Explanation (See note 2.)
setting
100/200 V
setting
400 V
g
range
power?
Pn500
Positioning
completion
range 1
Sets the range of positioning completed output 1
(INP1).
3
7
Command
unit
0 to 250 ---
Pn501
Position
lock
rotation
speed
Sets the number of rotations for position lock during
speed control.
10
10
r/min
0 to
10000
---
Pn502
Rotation
speed for
motor
rotation
detection
Sets the number of rotations for the Servomotor
rotation detection output (TGON).
20
20
r/min
1 to
10000
---
Pn503
Speed
conformity
signal
output
width
Sets the allowable fluctuation (number of rotations) for
the speed conformity output (VCMP).
10
10
r/min
0 to 100 ---
Pn504
Positioning
completion
range 2
Sets the range for positioning completed output 2
(INP2).
3
7
Command
unit
1 to 250 ---
Pn505
Deviation
counter
overflow
level
Sets the detection level for the deviation counter over
alarm.
1024
1024
x 256
command
unit
1 to
32767
---
Pn506
Brake
timing 1
Sets the delay from the brake command to the
Servomotor turning OFF.
0
0
x 10 ms
0 to 50
---
Pn507
Brake
command
speed
Sets the spread for outputting the brake command.
100
100
r/min
0 to
10000
---
Pn508
Brake
timing 2
Sets the delay time from the Servomotor turning OFF
to the brake command output.
50
50
x 10 ms
10 to
100
---
Pn509
Momentary
hold time
Sets the time during which alarm detection is disabled
when a power failure occurs.
20
20
ms
20 to
1000
---
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]