4-7
D
Absolute Encoder Setup (Fn008) in System Check Mode
Absolute encoder setup in
System Check Mode
PGCL1 displayed.
PGCL5 set.
Setup operation
Flashing donE displayed
(setup complete).
(1 s later)
Returns to PGCL5.
1 s min.
1 s min.
D
Operation Procedure
PR02W
operation
Front panel
key operation
Display example
Explanation
Status Display Mode. (See note.)
Press the MODE/SET Key to change to System Check
Mode.
Press the Up or Down Key to select function Fn008.
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to enter the absolute encoder setup functions. PGCL1
will be displayed.
Press the Up Key to display PGCL5.
Press the MODE/SET Key to set up the absolute
encoder. When setup is complete, “donE” will flash for
approximately 1 s.
(Approx. 1 s later)
After “donE” has been displayed, the display will return
to “PGCL5.”
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s min.)
to display the System Check Mode function code.
Note
When connecting a Servomotor with an absolute encoder and turning ON the power for the first
time, A.81 (backup error) will be displayed.
D
Turn ON the Power
The alarm (A.81) will not be cancelled with the setup operation. Turn OFF the power (and check that
the power indicator is not lit), then turn ON the power again to cancel the alarm. After the power is
turned ON again, as long as there is no error, the setup procedure is complete at this point. If an alarm
(A.81) occurs, repeat the previous step.
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]