4-23
Para-
meter
No.
Restart
power?
Setting
range
Unit
Default
setting
400 V
Default
setting
100/200 V
Explanation (See note 1.)
Parameter
name
Para-
meter
No.
Restart
power?
Setting
range
Unit
Default
setting
400 V
Default
setting
100/200 V
Explanation (See
note 2.)
Setting
Name
Digit
No.
Parameter
name
Pn122
Not used.
(Do not change setting.)
0
0
---
---
---
Pn123
Not used.
(Do not change setting.)
0
0
---
---
---
Note 1.
Explanation for parameters set using 5 digits.
Note 2.
Explanation for parameters requiring each digit No. to be set separately.
H
Position Control Parameters (From Pn200)
Para-
Parameter
Explanation (See note 1.)
Default
tti
Default
tti
Unit
Setting
Restart
?
meter
No.
name
Digit
No.
Name
Set-
ting
Explanation (See note
2.)
setting
100/200 V
setting
400 V
g
range
power?
Pn200
Position
control
setting 1
0
Command
pulse
mode
0
Feed pulse
forward/reverse signal:
Positive logic
1011
0000
---
---
Yes
g
1
Forward pulse/reverse
pulse: Positive logic
2
90
°
phase difference (A/B
phase) signal (x1):
Positive logic
3
90
°
phase difference (A/B
phase) signal (x2):
Positive logic
4
90
°
phase difference (A/B
phase) signal (x4):
Positive logic
5
Feed
pulses/Forward/reverse
signal: Negative logic
6
Forward pulse/reverse
pulse: Negative logic
7
90
°
phase difference (A/B
phase) signal (x1):
Negative logic
8
90
°
phase difference (A/B
phase) signal (x2):
Negative logic
9
90
°
phase difference (A/B
phase) signal (x4):
Negative logic
1
Deviation
0
High level signal
counter
reset
1
Rising signal (low to high)
reset
2
Low level signal
3
Falling signal (low to high)
2
Deviation
counter
reset if an
alarm
0
Deviation counter reset if
an alarm occurs when
Servomotor is OFF.
alarm
occurs
when the
Servomot
1
Deviation counter not
reset if an alarm occurs
when Servomotor is OFF.
Servomot
or is OFF
2
Deviation counter reset
2
Deviation counter reset
only if alarm occurs.
3
Pulse
command
filter
l ti
0
Command filter for line
driver signal input (500
kpps)
selection
1
Command filter for
open-collector signal input
(200 kpps)
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]