4-36
•
Settings are the same as for Pn50A.1.
•
If Pn50A.0 is set to 0, you cannot change the pin number. Settings 0 to 6 and 9 to F are disabled, and all
are set to CN1, pin 42 enabled by L input. Settings 7 and 8 are both enabled.
•
To change the pin number, set Pn50A.0 to 1.
•
If set to 7 (always ON), the servo is in always overtravel status (i.e., forward rotation is always drive-
prohibited).
•
If set to 8 (always OFF), the servo drive prohibition is OFF (i.e., the forward rotation drive is permitted).
•
The POT signal permits forward rotation drive upon input.
Pn50b.0
Input signal selection 2 --- NOT signal (reverse drive prohibited) input terminal allocation (All
operation modes)
Setting
range
0 to F
Unit
---
Default
setting
8
Restart
power?
Yes
•
Settings are the same as for Pn50A.1.
•
If Pn50A.0 is set to 0, you cannot change the pin number. Settings 0 to 6 and 9 to F are disabled, and all
are set to CN1, pin 43 enabled by L input. Settings 7 and 8 are both enabled.
•
To change the pin number, set Pn50A.0 to 1.
•
If set to 7 (always ON), the servo is in always in overtravel status (i.e., reverse rotation is always drive-
prohibited).
•
If set to 8 (always OFF), the servo drive prohibition is OFF (i.e., the reverse rotation drive is permitted).
•
The NOT signal permits reverse rotation drive upon input.
Pn50b.1
Input signal selection 2 --- RESET signal (alarm reset) input terminal allocation (All operation
modes)
Setting
range
0 to F
Unit
---
Default
setting
4
Restart
power?
Yes
•
Settings are the same as for Pn50A.1.
•
If Pn50A.0 is set to 0, you cannot change the pin number. Settings 0 to 6 and 9 to F are disabled, and all
are set to CN1, pin 44 enabled by L input. Settings 7 and 8 are both enabled.
•
To change the pin number, set Pn50A.0 to 1.
•
Do not set 7 (always ON).
•
If setting 8 (always OFF), when the alarm is cancelled, turn ON the power or reset the alarm using the
operation keys.
Pn50b.2
Input signal selection 2 --- PCL signal (forward rotation current limit) input terminal allocation
(All operation modes)
Setting
range
0 to F
Unit
---
Default
setting
5
Restart
power?
Yes
•
Settings are the same as for Pn50A.1.
•
If Pn50A.0 is set to 0, you cannot change the pin number. Settings 0 to 6 and 9 to F are disabled, and all
are set to CN1, pin 45 enabled by L input. Settings 7 and 8 are both enabled.
•
To change the pin number, set Pn50A.0 to 1.
Pn50b.3
Input signal selection 2 --- NCL signal (reverse rotation current limit) input terminal allocation
(All operation modes)
Setting
range
0 to F
Unit
---
Default
setting
6
Restart
power?
Yes
Operation
Chapter 4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]