6-16
Para-
meter
No.
Restart
power?
Setting
range
Unit
Default
setting
400 V
Default
setting
100/200 V
Explanation
Parameter
name
Pn307
Speed com-
mand filter time
constant
Sets constant during filter of speed command
voltage input (REF).
40
40
x 0.01 ms
0 to
65535
---
Pn308
Speed feed-
back filter time
constant
Sets constant during filter of speed feedback.
0
0
x 0.01 ms
0 to
65535
---
H
Torque Control Parameters (From Pn400)
Parame-
Parameter
Explanation (See note 1.)
Default
tti
Default
tti
Unit
Setting
Restart
?
ter No.
name
Digit
No.
Name
Set-
ting
Explanation (See note 2.)
setting
100/200 V
setting
400 V
g
range
power?
Pn400
Torque
command
scale
Sets the torque command voltage (TREF) to output
the rated torque.
30
30
0.1 V/
rated
torque
10 to
100
---
Pn401
Torque
command
filter time
constant
Sets the constant when filtering the internal torque
command.
40
100
x 0.01
ms
0 to
65535
---
Pn402
Forward
torque limit
Forward rotation output torque limit (rated torque
ratio).
350
800
%
0 to 800
---
Pn403
Reverse
torque limit
Reverse rotation output torque limit (rated torque
ratio).
350
800
%
0 to 800
---
Pn404
Forward
rotation
external
current limit
Output torque limit during input of forward rotation
current limit (rated torque ratio)
100
100
%
0 to 800
---
Pn405
Reverse
rotation
external
current limit
Output torque limit during input of reverse rotation
current limit (rated torque ratio)
100
100
%
0 to 800
---
Pn406
Emergency
stop torque
Deceleration torque when an error occurs (rated
torque ratio)
350
800
%
0 to 800
---
Pn407
Speed limit
Sets the speed limit in torque control mode.
3000
10000
r/min
0 to
10000
---
Pn408
Torque
d
0
Selects
h fil
0
Function not used.
0000
0000
---
---
---
q
command
setting
notch filter
function.
1
Notch filter used for torque
commands.
1 to
3
Not used.
0
(Do not change setting.)
Pn409
Notch filter
frequency
Sets notch filter frequency for torque command
2000
2000
Hz
50 to
2000
---
Note 1.
Explanation for parameters set using 5 digits.
Note 2.
Explanation for parameters requiring each digit No. to be set separately.
H
Sequence Parameters (From Pn500)
Para-
Parameter
Explanation (See note 1.)
Default
tti
Default
tti
Unit
Setting Restart
?
meter
No.
name
Digit
No.
Name
Set-
ting
Explanation (See note 2.)
setting
100/200 V
setting
400 V
g
range
power?
Pn500
Positioning
completion
range 1
Sets the range of positioning completed output 1
(INP1).
3
7
Command
unit
0 to 250 ---
Pn501
Position
lock
rotation
speed
Sets the number of rotations for position lock during
speed control.
10
10
r/min
0 to
10000
---
Appendix
Chapter 6
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]