4-116
H
Analog Monitor Output Connector (CN5)
•
The Analog Monitor Output Connector (CN5) is located inside the top cover of the Servo Driver.
Note
There is no top cover on model R88D-WT60H (6kW). Instead, CN5 is to the right of the display
and settings area.
Analog Monitor Output
Connector (CN5)
CN5 pin distribution (front panel view)
Driver pin header: DF11-4DP-2DS
Cable connector socket: DF11-4DS-2C
Cable connector contact: DF11-2428SCF
(Manufactured by Hirose.)
View with upper cover open
Pin No.
Symbol
Name
Function and interface
1
NM
Analog monitor 2
Default setting: Speed monitor 1 V / 1000 r/min. (change
using Pn003.1)
2
AM
Analog monitor 1
Default setting: Current monitor 1 V / rated torque
(change using Pn003.0)
3
GND
Analog monitor ground Ground for analog monitors 1 and 2
4
GND
Analog monitor ground
g
Note 1.
Displays status with no change to scaling.
Note 2.
Maximum output voltage is
±
8 V. Exceeding this value may result in an abnormal output.
Note 3.
Output accuracy is approximately
±
15%.
H
Analog Monitor Output Circuit
Servo Driver
NM (analog monitor 2)
AM (analog monitor 1)
GND (analog monitor ground)
GND (analog monitor ground)
Operation
Chapter 4