6-2
6-1
Connection Examples
H
Connection Example 1: Connecting to SYSMAC
C200HW-NC113/213/413 Position Control Units
R88D-WT
j
R88M-W
j
Encoder Cable
R88A-CRW
j
Power Cable
R88A-CAW
j
Class-3 ground
No
ise
filte
r
Main circuit power supply
C200H-NC113/213/413
3-phase 200/230 V AC 50/60Hz
Main circuit contact
Surge killer
DC reactor
Red
White
Blue
Green/
Yellow
Contents
24-V DC input (for output)
0-V input (for output)
CCW (with a resistor)
CCW (without a resistor)
CW (with a resistor)
CW (without a resistor)
P
ul
se
output
X-axis origin line driver input
X-axis dev. cntr. reset output
X-axis CW limit input
X-axis positioning complete input
X-axis origin common
X-axis input common
X-axis emerg. stop input
X-axis external interrupt input
X-axis CCW limit input
X-axis origin proximity input
Shell
24 V DC
24 V DC
24 V DC
Note 1.
The example shows a three-phase, 200-V AC input to the Servo Driver for the main circuit
power supply. Be sure to provide a power supply and wiring conforming to the power supply
specifications for the Servo Driver in use.
Note 2.
Incorrect signal wiring can cause damage to Units and the Servo Driver.
Note 3.
Leave unused signal lines open and do not wire them.
Note 4.
Use mode 2 for origin search.
Note 5.
Use the 24-V DC power supply for command pulse signals as a dedicated power supply.
Note 6.
The diode recommended for surge absorption is the ERB44-02 (Fuji Electric).
Note 7.
Make the setting so that the Servo can be turned ON and OFF with the RUN signal.