Appendix to the operating instructions
8103851
2018-12a
[8103853]
Translation of the original instructions
Energy throughfeed DRRD-...-P..E..
English
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For all available product documentation
è
www.festo.com/pk
Note
Observe the warnings and instructions in the operating instructions for the
DRRD semi-rotary drive.
1
Control sections and connections
DRRD-...-P.. (pneumatic)
1
2
4
5
7
DRRD-...-P..E.. (pneumatic and electric)
1
2
3
4
6
5
7
1
Through-hole for mounting the
DRRD (2x)
2
Supply port P1 ... P8 (output)
3
Electrical output S1 ... S8 (socket)
4
Mounting interface for working
load (4x)
5
Supply port P1 ... P8 (input)
6
Electrical input S1 ... S8 (plug)
7
Housing
Fig. 1
2
Function and application
The energy throughfeed DRRD-...-P..E.. serves to permit the passage of com
pressed air and electrical signals through the drive shaft of the DRRD semi-rotary
drive.
3
Installation
3.1 Installation, mechanical
Affix the DRRD with two screws to holes
1
and with 2 centring sleeves to the
housing
7
.
Affix the working load with at least two screws positioned opposite one another
to the drive flange, and with centring sleeves to threads
4
.
Tightening torques are shown in the table below.
4
1
7
Fig. 2
Size
16
20
25
32
35
40
50
63
Mounting of DRRD
Screw in
1
(direct mounting)
M5
M5
M6
M8
M8
M10
M10
M12
Tightening torque
[Nm]
6
6
10
18
18
30
30
55
Screw through
1
(through-fastening)
M4
M4
M5
M6
M6
M8
M8
M10
Tightening torque
[Nm]
3
3
6
10
10
18
18
30
Centring sleeve ZBH
[mm]
9
9
12
15
15
15
15
25
Mounting of working load
Screw in
4
M4
M4
M5
M6
M6
M6
M8
M10
Tightening torque
[Nm]
3
3
6
10
10
10
20
40
Centring sleeve ZBH
[mm]
7
7
9
9
9
9
12
15
Fig. 3
3.2 Installation, pneumatic
If using the energy throughfeed with pneumatic connections DRRD−...−
P..
:
Connect tubes to pneumatic connections
2
and
5
.
Corresponding port identifications are used to indicate which tube to fit to
which push-in fitting (tubing dimensions
è
Fig. 8).
2
5
Fig. 4
3.3 Installation, electric
Warning
Danger of short circuit! If one of the electrical inputs
6
is supplied with voltage,
there will be voltage at all electrical inputs, because the positive and negative
lines are connected together inside the component.
Ensure that the electrical inputs
6
share a common voltage source.
Otherwise the DRRD may be irreparably damaged by large compensating
currents.
Leave the cover caps on the unused plugs
6
.
The plugs
6
on the side of the housing are not protected in any other way
against accidental contact.