background image

DRRD-...-P..E..

Festo AG & Co. KG

Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com

Appendix to the operating instructions

8103851
2018-12a
[8103853]

Translation of the original instructions

Energy throughfeed DRRD-...-P..E..

English

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

For all available product documentation 

è

 www.festo.com/pk

Note

 Observe the warnings and instructions in the operating instructions for the

DRRD semi-rotary drive.

1

Control sections and connections

DRRD-...-P.. (pneumatic)

1

2

4

5

7

DRRD-...-P..E.. (pneumatic and electric)

1

2

3

4

6

5

7

1

Through-hole for mounting the
DRRD (2x)

2

Supply port P1 ... P8 (output)

3

Electrical output S1 ... S8 (socket)

4

Mounting interface for working
load (4x)

5

Supply port P1 ... P8 (input)

6

Electrical input S1 ... S8 (plug)

7

Housing

Fig. 1

2

Function and application

The energy throughfeed DRRD-...-P..E.. serves to permit the passage of com­
pressed air and electrical signals through the drive shaft of the DRRD semi-rotary
drive.

3

Installation

3.1 Installation, mechanical

 Affix the DRRD with two screws to holes 

1

 and with 2 centring sleeves to the

housing 

7

.

 Affix the working load with at least two screws positioned opposite one another

to the drive flange, and with centring sleeves to threads 

4

.

Tightening torques are shown in the table below.

4

1

7

Fig. 2

Size

16

20

25

32

35

40

50

63

Mounting  of DRRD

Screw in 

1

 

(direct mounting)

M5

M5

M6

M8

M8

M10

M10

M12

Tightening torque

[Nm]

6

6

10

18

18

30

30

55

Screw through 

1

 

(through-fastening)

M4

M4

M5

M6

M6

M8

M8

M10

Tightening torque

[Nm]

3

3

6

10

10

18

18

30

Centring sleeve ZBH

[mm]

9

9

12

15

15

15

15

25

Mounting of working load

Screw in 

4

M4

M4

M5

M6

M6

M6

M8

M10

Tightening torque

[Nm]

3

3

6

10

10

10

20

40

Centring sleeve ZBH

[mm]

7

7

9

9

9

9

12

15

Fig. 3

3.2 Installation, pneumatic

If using the energy throughfeed with pneumatic connections DRRD−...−

P..

:

 Connect tubes to pneumatic connections 

2

 and 

5

.

Corresponding port identifications are used to indicate which tube to fit to
which push-in fitting (tubing dimensions 

è

 Fig. 8).

2

5

Fig. 4

3.3 Installation, electric

Warning

Danger of short circuit! If one of the electrical inputs 

6

 is supplied with voltage,

there will be voltage at all electrical inputs, because the positive and negative
lines are connected together inside the component.
 Ensure that the electrical inputs 

6

 share a common voltage source.

Otherwise the DRRD may be irreparably damaged by large compensating
currents.

 Leave the cover caps on the unused plugs 

6

.

The plugs 

6

 on the side of the housing are not protected in any other way

against accidental contact.

Reviews: