background image

Note

 Only use connection accessories with a straight plug

(Accessories 

è

 www.festo.com/catalogue) at electrical connections 

3

and 

6

.

If using the energy throughfeed with electrical connections DRRD−...−P..

E..

:

 Connect lines to electrical connections 

3

 and 

6

.

Corresponding port identifications (A) are used to indicate which plug to plug
into which socket.

(A)

3

6

Fig. 5

Pin allocation DRRD-16/20-...-P2E2 

1)

Electrical  connection

Input

Output

Number of connections

2 (plug 

6

)

2 (sockets 

3

)

Designation (A)

S1, S2

S1, S2

Circuit diagram

1)

All contacts 1 (positive) connected with one another. 
All contacts 3 (negative) connected with one another.

Pin allocation DRRD-25/32/35-...-P4E6 

1)

Electrical connection

Input

Output

Number of connections

3 (plug 

6

)

6 (sockets 

3

)

Designation (A)

S1;S2, S3;S4, S5;S6

S1, S2, S3, S4, S5, S6

Circuit diagram

1)

All contacts 1 (positive) connected with one another. 
All contacts 3 (negative) connected with one another.

Pin allocation DRRD-40/50/63-...-P8E8 

1)

Electrical connection

Input

Output

Number of connections

4 (plug 

6

)

4 (sockets 

3

)

Designation (A)

S1;S2, S3;S4, S5;S6, S7;S8

S1;S2, S3;S4, S5;S6, S7;S8

Circuit diagram

1)

All contacts 1 (positive) connected with one another. 
All contacts 3 (negative) connected with one another.

Fig. 6

In DRRD-...-P4E6, two electrical outputs 

3

 are assigned to each electrical out­

put 

6

.

6

3

Fig. 7

4

Technical data

Size

16

20

25

32

35

40

50

63

Pneumatic specifications (DRRD-...-P..)

Number of pneumatic
connections

2

4

8

Tubing O.D.

[mm]

4

Max. operating pressure

[bar]

8

Flow rate per channel

[l/min] 86

33

Electrical specifications (DRRD-...-P..E..)

Rated voltage

[V]

30

Max. perm. current per sig­
nal line 

1)

[A]

1.5

Cable cross section

[mm

2

]

0.14

Number of signal lines

2

6

8

Electrical connection

M8

M12

Materials

Housing

Anodised aluminium

Plug

PA, CuZn, NBR, PU

Weight (energy throughfeed only)

P..

[kg]

0.32

0.35

0.71

0.92

1.09

1.47

1.95

2.25

P..E..

[kg]

0.46

0.48

0.72

0.90

0.88

1.77

2.33

2.61

1)

The positive and negative lines of all electrical connections are connected together. The combined
maximum peak current for this common positive and negative line is likewise 1.5 A.

Fig. 8