PR 5500 Instrument Manual
Device Installation
Sartorius EN-51
4.4.1.7
Connecting 4 Load Cells
PR 6204 ‚Pendeo® Process‘/PR 6224 ‚Pendeo® Truck‘
via
RS-485
Example
or screen clamping rail/
oder Schirmklemmschiene
1 2 3 4 5 6 7 8
↓
ON
{
{
RS-485-A
RS-485-B
RS-485-B
RS-485-A
RS 5500 with/mit
PR 5500/04
screen/Schirm
screen/Schirm
+
–
B
A
rd
bu
gn
gy
LC 1
+
–
B
A
rd
bu
gn
gy
LC 3
+
–
B
A
rd
bu
gn
gy
LC 4
+
–
B
A
rd
bu
gn
gy
LC 2
PS
IND
PR 6024/64S
24 V DC
LED
1 AT
+ – B A
230 V AC
L
N
PE
+
GND
24 V DC
1 A
PE – +
PR 6024/62S
rd
bu
gn
gy
PR 6124/xxP
PR 6124/xxD
equipotential bonding conductor
Potenzialausgleich
B
A
Note
For more information, see the load cell and junction box manuals.