12. Serial RapidIO Registers > RapidIO Error Management Extension Registers
295
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
Bits
Name
Description
Type
Reset
Value
0
IMP_SPEC_ERR
Implementation Specific Error
Detected Logical/Transport error per port. This bit indicates one or
more of the following illegal field errors:
• Reserved transport type (TT) detected (TT field = 10 or 11 for all
but maintenance packets with hop count = 0)
• Maximum retry threshold exceeded
• Unmapped destination ID error
• Parity Error in Lookup Table
• ISF TEA error
• Multicast TEA error
• Port error
Note: Clearing all the bits in this register also clears the following
interrupt status bits in the
“RapidIO Port x Interrupt Status Register”
• MAX_RETRY
• TEA
• MC_TEA
• LUT_PAR_ERR
• ILL_TRANS_ERR
Caution: The Error Capture register information is only valid for
Reserved Transport Type Detected errors and Unmapped DestID
errors. For the Max Retry errors the information latched is the last
packet received, not the packet that was retried.
For more information on error capture, see
Capture Attributes CSR and Debug 0” on page 299
.
R/W0C
0
1:8
Reserved
N/A
R
0
9
CS_CRC_ERR
Received a control symbol with a CRC error.
R/W0C
0
10
CS_ILL_ID
Received an acknowledge control symbol with an unexpected
ackID (packet-accepted or packet_retry).
The Capture register does not have valid information during this
error detection.
R/W0C
0
11
CS_NOT_ACC
Received packet-not-accepted control symbol.
R/W0C
0
12
PKT_ILL_ACKID
Received packet with unexpected ackID.
R/W0C
0
13
PKT_CRC_ERR
Received a packet with a CRC error.
R/W0C
0
14
PKT_ILL_SIZE
Received packet exceeds 276 bytes.
R/W0C
0
15:25
Reserved
N/A
R