12. Serial RapidIO Registers > Utility Unit Registers
388
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.12
Utility Unit Registers
The utility block contains global registers for interrupts and clocking.
12.12.1
Global Interrupt Status Register
This register indicates which block within the Tsi578 has generated an interrupt. The interrupt requests
from a given block are “ORed” together and the value of the output is reflected in this register.
Register name: GLOB_INT_STATUS
Reset value: 0x0000_0000
Register offset: 1AC00
Bits
0
1
2
3
4
5
6
7
00:07
Reserved
RCS
MCS
I2C
TEA
08:15
Reserved
MC_LAT Reserved
16:23
PORT15
PORT14
PORT13
PORT12
PORT11
PORT10
PORT9
PORT8
24:31
PORT7
PORT6
PORT5
PORT4
PORT3
PORT2
PORT1
PORT0
Bits
Name
Description
Type
Reset
Value
0:3
Reserved
N/A
Note: These upper 4 bits are reserved in order to be compatible with the
I2C IP. Refer to the I2C Chapter.
R
0
4
RCS
Combined 4 Reset Control Symbols interrupt status from all ports
R
0
5
MCS
Combined Multicast-Event Control Symbol interrupt status from all ports
R
0
6
I2C
I
2
C Interrupt Port
R
0
7
TEA
“Fabric Interrupt Status Register” on
to determine what port(s) experienced the TEA.
R
0
8:13
Reserved
N/A
R
0
14
MC_LAT
At least one broadcast buffer has exceeded its maximum multicast
latency timeout. Refer to
“RapidIO Broadcast Buffer Maximum Latency
Expired Error Register” on page 384
to find out which ports have
experienced this error.
R
0
15
Reserved
N/A
R
0
16
PORT15
Port 15 Interrupt
R
0
17
PORT14
Port 14 Interrupt
R
0
18
PORT13
Port 13 Interrupt
R
0