12. Serial RapidIO Registers > RapidIO Physical Layer Registers
275
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.6.5
RapidIO Serial Port x Link Maintenance Response CSR
This register is accessed by an external RapidIO device. A read of this register returns the status from
the last link-response received from the link-partner due to a link-request/input-status issued using the
RapidIO Serial Port x Link Maintenance Request CSR CSR or the RapidIO Port x Control Symbol
Transmit register.
Register name: SP{0..15}_LM_RESP
Reset value: 0x0000_0000
Register offset: 144, 164, 184, 1A4, 1C4, 1E4, 204, 224,
244, 264, 284, 2A4, 2C4, 2E4, 304, 324
Bits
0
1
2
3
4
5
6
7
00:07
RESP_VLD
Reserved
08:15
Reserved
16:23
Reserved
ACK_ID_STAT
24:31
ACK_ID_STAT
LINK_STAT
Bits
Name
Description
Type
Reset
Value
0
RESP_VLD
Response Valid
0 = No link-response control symbol received or no link-request/reset
transmitted
1 = If the link-request was a link-request/input-status, this bit indicates
that the link-response control symbol has been received. The
LINK_STAT field contains information pertaining to that link response.
If link-request was a link-request/reset, this bit indicates that the
link-request/reset has been transmitted.
Note: For link-response control symbols, this bit certifies the availability
of data, it does not certify the correctness of the data.
RC
0
1:21
Reserved
N/A
R
0
22:26
ACK_ID_STAT
AckID Status
AckID status field from the link-response control symbol. The value of
the next ackID expected by the receiver.
R
0
27:31
LINK_STAT
Link Status
Link status field from the link-response control symbol. Other values
are reserved.
0b00010 = Error
0b00100 = Retry-stopped
0b00101 = Error-stopped
0b10000 = OK
R
0