11. Signals > Signal Groupings
224
Tsi578 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
S_CLK_p
I, CML
Differential reference clock at 156.25MHz. The
clock is used as a reference clock for the SerDes
and as a source for the internal logic clocks.
These signals are internally terminated.
The S_CLK inputs should be ac-coupled.
AC coupling capacitor of 0.1uF
required.
If this clock input is not used, pull
this signal up to SP_VDD with a
10K resistor.
S_CLK_n
I, CML
AC coupling capacitor of 0.1uF
required.
If this clock input is not used, pull
this signal down to VSS with a
10K resistor.
HARD_RST_b I,
LVTTL,
Hyst, PU
Schmidt-triggered hard reset. Asynchronous active
low reset for the entire device.
Connect to a power-up reset
source. Refer to the
Tsi578
Hardware Manual
for more
information.
Interrupts
INT_b O,
OD,
LVTTL
Interrupt signal (open drain output)
External pull-up required.
Pull up to VDD_IO through a
10K resistor.
SW_RST_b O,
OD,
LVTTL
Software reset (open drain output): This signal is
asserted when a RapidIO port receives a valid
reset request on a RapidIO link. If self-reset is not
selected, this pin remains asserted until the reset
request is cleared from the status registers. If
self-reset is selected, this pin remains asserted
until the self reset is complete. If the Tsi578 is reset
from the HARD_RST_b pin, this pin is de-asserted
and remains de-asserted after HARD_RST_b is
released. For more information, see
Note: SW_RST_b is the only external indicator
that a reset request has been received, and should
be handled as an interrupt. Port-writes cannot be
sent for notification of reset request reception.
External pull-up required. Pull up
to VDD_IO through a 10K
resistor.
Multicast
MCES
I/O,
LVTTL,
PD
Multicast Event Control Symbol
As an input, an edge (rising or falling) triggers a
Multicast Event Control Symbol to be sent to all
enabled ports.
As an output, this pin toggles its value every time
an Multicast Event Control Symbol is received by
any port which is enabled for Multicast Event
Control Symbols.
This signal must remain stable for 10 P_CLK
cycles before and after a transition.
No termination required. This pin
must not be driven by an
external source until all power
supply rails are stable.
Table 31: Tsi578 Signal Descriptions (Continued)
Pin Name
Type
Description
Recommended Termination
a