8.7 Message List
162
:ESR2?
Query of event status register 2
*1
:ESR3?
Query of event status register 3
*1
Measurement Frequency
:FREQuency
120/ 1000 (NR1)
Setting of measurement frequency
*2, 3
:FREQuency?
Query of measurement frequency
*1, 2
Communication Handshake
:HANDshake
OFF/ X/ HARDware/
BOTH
Setting of RS-232C communication hand-
shake
*2,3,7
:HANDshake?
Query of RS-232C communication hand-
shake
*1,2,7
Header
:HEADer
ON/ OFF
Setting of header for response messages
*2, 3
:HEADer?
Query of header for response messages
*1, 2
EXT I/O Output
:IO:OUTPut:DELay
ON/ OFF
Setting of delay time for judgement result out-
put and EOM output period in EXT I/O
*2, 3
:IO:OUTPut:DELay?
Query of delay time for judgement result Out-
put and EOM output period in EXT I/O
*1, 2
:IO:RESult:RESet
ON/ OFF
Setting of output of judgment result signal line
in EXT I/O
*2, 3
:IO:RESult:RESet?
Query of output of judgment result signal line
in EXT I/O
*1, 2
Judgment Mode
:JUDGment:MODE
COUNt/ DEViation
Setting of judgment mode of comparator and
BIN functions
*2, 3
:JUDGment:MODE?
Query of judgment mode of comparator and
BIN functions
*1, 2
Unique Commands
Command
Data Section
Explanation
Error
Refer-
ence
Page
Error Explanations (An error is generated when a message is executed in the following cases)
*1 Query Error _______ When a response message exceeds 10 kB
*2 Execution Error ____ When a command is executed while open circuit, short circuit, or load compensation
*3 Execution Error ____ When set to other than the specified character data or numeric data.
*4 Execution Error ____When a number that has not been saved is specified.
*5 Execution Error ____When a command is executed during comparator measurement or BIN measure-
ment.
*6 Execution Error ____When not even one measurement value is saved to memory.
*7 Execution Error ____When there is an RS-232C specific command or query while the interface type is set
to GP-IB.
*8 Execution Error ____When a command to display a reference value in the SUB display area is executed
while the count setting is configured.
Note: Command errors are generated for all messages with a misspelling.
Summary of Contents for 3504-40 C HiTester
Page 2: ......
Page 22: ...1 4 Names and Functions of Parts 16 ...
Page 28: ...2 5 Turning the Power On and Off 22 ...
Page 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Page 66: ...4 4 Self Calibration 60 ...
Page 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Page 136: ...7 4 About Measurement Times 130 ...
Page 286: ...Appendix 7 Initial Settings Table A14 ...
Page 289: ......
Page 290: ......
Page 291: ......
Page 292: ......