GE Multilin
F60 Feeder Protection System
B-77
APPENDIX B
B.4 MEMORY MAPPING
B
E8D3
Aggregator 1 Include PMU5
0 to 1
---
1
F126
0 (No)
E8D4
Aggregator 1 Include PMU6
0 to 1
---
1
F126
0 (No)
E8D5
PMU Aggregator 1 ASDUS
1 to 4
---
1
F001
1
E8D6
PMU Aggregator 1 Port
1 to 3
---
1
F001
1
E8D7
PMU Aggregator 1 Reserved (3 items)
0 to 1
---
1
F001
0
Phasor Measurement Unit Aggregator Control Block (Read/Write Setting)
E9C8
PMU Aggregator 1 Control Block SvEna
0 to 4294967295
---
1
F300
0
E9CA
PMU Aggregator 1 Control Block Client Control
0 to 4294967295
---
1
F300
0
E9CC
PMU Aggregator 1 CB SvEna Default
0 to 4294967295
---
1
F300
0
E9CE
PMU Aggregator 1 Control Block ConfRev
1 to 4294967295
---
1
F003
1
E9D0
PMU Aggregator 1 Control Block Priority
0 to 7
---
1
F001
4
E9D1
PMU Aggregator 1 Control Block IPClass
0 to 1
---
1
F563
1 (Expedited
Forwarding)
E9D2
PMU Aggregator 1 Control Block VID
0 to 4095
---
1
F001
0
E9D3
PMU Aggregator 1 Control Block APPID
0 to 16383
---
1
F001
0
E9D4
PMU Aggregator 1 Control Block IP Address
0 to 4294967295
---
1
F003
0
E9D6
PMU Aggregator 1 Control Block Security
0 to 2
---
1
F001
0
Phasor Measurement Unit Recording Command (Read/Write Command)
EA22
PMU 1 Recording Clear Command
0 to 1
---
1
F126
0 (No)
EA23
PMU 1 Recording Force Trigger
0 to 1
---
1
F126
0 (No)
Phasor Measurement Unit Recording (Read/Write Setting)
EA2E
PMU 1 Record Function
0 to 1
---
1
F102
0 (Disabled)
EA2F
PMU 1 No of Timed Records
2 to 128
---
1
F001
10
EA30
PMU 1 Trigger Mode
0 to 1
---
1
F542
0 (Auto
Overwrite)
EA31
.PMU 1 Timed Trigger Position
1 to 50
%
1
F001
10
Phasor Measurement Unit Recording Ex (Read/Write Setting)
Phasor Measurement Unit Triggering (Read/Write Setting)
EA4A
PMU 1 User Trigger
0 to 4294967295
---
1
F300
0
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
EA56
PMU 1 Volt Trigger Function
0 to 1
---
1
F102
0 (Disabled)
EA57
PMU 1 Voltage Trigger Low Volt
0.25 to 1.25
pu
0.001
F001
800
EA58
PMU 1 Voltage Trigger High Volt
0.75 to 1.75
pu
0.001
F001
1200
EA59
PMU 1 Voltage Trigger Pkp Time
0 to 600
s
0.01
F001
10
EA5A
PMU 1 Voltage Trigger Dpo Time
0 to 600
s
0.01
F001
100
EA5B
PMU 1 Voltage Trigger Block (3 items)
0 to 4294967295
---
1
F300
0
EA61
PMU 1 Voltage Trigger Target
0 to 2
---
1
F109
0 (Self-reset)
EA62
PMU 1 Voltage Trigger Events
0 to 1
---
1
F102
0 (Disabled)
Phasor Measurement Unit Current Trigger (Read/Write Setting
EAA4
PMU 1 Current Trigger Function
0 to 1
---
1
F102
0 (Disabled)
EAA5
PMU 1 Current Trigger Pickup
0.1 to 30
pu
0.001
F001
1800
EAA6
PMU 1 Current Trigger Pkp Time
0 to 600
s
0.01
F001
10
EAA7
PMU 1 Current Trigger Dpo Time
0 to 600
s
0.01
F001
100
EAA8
PMU 1 Current Trigger Block (3 items)
0 to 4294967295
---
1
F300
0
EAAE
PMU 1 Current Trigger Target
0 to 2
---
1
F109
0 (Self-reset)
EAAF
PMU 1 Current Trigger Events
0 to 1
---
1
F102
0 (Disabled)
Phasor Measurement Unit Frequency Trigger (Read/Write Setting)
EAEC
PMU 1 Frequency Trigger Function
0 to 1
---
1
F102
0 (Disabled)
EAED
PMU 1 Frequency Trigger Low Frequency
20 to 70
Hz
0.01
F001
4900
EAEE
PMU 1 Frequency Trigger High Frequency
20 to 70
Hz
0.01
F001
6100
EAEF
PMU 1 Frequency Trigger Pickup Time
0 to 600
s
0.01
F001
10
EAF0
PMU 1 Frequency Trigger Dropout Time
0 to 600
s
0.01
F001
100
EAF1
PMU 1 Frequency Trigger Block (3 items)
0 to 4294967295
---
1
F300
0
EAF7
PMU 1 Frequency Trigger Target
0 to 2
---
1
F109
0 (Self-reset)
EAF8
PMU 1 Frequency Trigger Events
0 to 1
---
1
F102
0 (Disabled)
Table B–10: MODBUS MEMORY MAP (Sheet 69 of 70)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for F60
Page 10: ...x F60 Feeder Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 138: ...4 28 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 454: ...5 316 F60 Feeder Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 500: ...7 14 F60 Feeder Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 508: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 522: ...10 12 F60 Feeder Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 660: ...B 116 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 706: ...E 10 F60 Feeder Protection System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Page 718: ...F 12 F60 Feeder Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 728: ...H 8 F60 Feeder Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 730: ...H 10 F60 Feeder Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...