Wiring ASDA-B2-F
3-18
September, 2015
3
3.3.3
Wiring Diagrams (CN1)
When the drive connects to inductive load, the diode has to be installed. (The permissible current
is under 40 mA. The surge current is under 100 mA.)
C1: Wiring of DO signal. The servo drive applies to
the external power and the resistor is general load.
R
24 V
DC
DOX-
Servo Drive
DOX+
DO1: (12,13)
DO2: (14,15)
DOX: (DOX+,DOX-)
X = 1,2
24 V
DC
50 mA
C2: Wiring of DO signal. The servo drive applies to
the external power and the resistor is inductive
load.
DOX-
Servo Drive
DOX+
DO1: (12,13)
DO2: (14,15)
DOX: (DOX+, DOX-)
X = 1,2
Ensure the polarity (+, -)
of diode is correct or it
may damage the drive.
24 V
DC
Input signal via relay or open-collector transistor
NPN
transistor, common emitter (E) mode (
SINK
mode)
C3
:
The wiring of DI. The servo drive applies to the external power.
24 V
DC
SON
COM+
Servo Drive
Approx. 4.7 K
Ω
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...