ASDA-B2-F Installation
September, 2015
2-5
2
2.5 Specification of Circuit Breaker and Fuse
Caution: Please use the fuse and circuit breaker that is recognized by UL/CSA.
Servo Drive Model
Circuit Breaker
Fuse (Class T)
Operation Mode
General
General
ASD-B2-0121-F 5A
5A
ASD-B2-0221-F 5A
6A
ASD-B2-0421-F 10A
10A
ASD-B2-0721-F 10A
20A
ASD-B2-1021-F 15A
25A
ASD-B2-1521-F 20A
40A
ASD-B2-2023-F 30A
50A
ASD-B2-3023-F 30A
70A
Note
:
If the servo drive equips with earth leakage circuit breaker for avoiding electric leakage, please choose the
current sensitivity which is over 200 mA and can continue up to 0.1 seconds.
2.6 EMI Filter Selection
Item
Power
Servo Drive Model
Recommended EMI Filter
Foot Print
1PH
3PH
1 100
W ASD-B2-0121-F RF007S21AA
RF022M43AA N
2 200
W ASD-B2-0221-F RF007S21AA
RF022M43AA N
3 400
W ASD-B2-0421-F RF007S21AA
RF022M43AA N
4 750
W ASD-B2-0721-F RF007S21AA
RF022M43AA N
5 1000
W ASD-B2-1021-F RF015B21AA
RF075M43BA
N
6 1500
W ASD-B2-1521-F RF015B21AA
RF075M43BA
N
7 2000
W ASD-B2-2023-F
-
RF037B43BA
N
8 3000
W ASD-B2-3023-F
-
RF037B43BA
N
EMI Filter Installation
All electronic equipment (including servo drive) generates high or low frequency noise during
operation and interfere the peripheral equipment via conduction or radiation. With EMI Filter and
the correct installation, much interference can be eliminated. It is suggested to use Delta’s EMI
Filter to suppress the interference better.
When installing servo drive and EMI Filter, please follow the instructions of the user manual and
make sure it meets the following specifications.
1. EN61000-6-4 (2001)
2. EN61800-3 (2004) PDS of category C2
3. A2 (2007) Class A Group 1
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...