Absolute System ASDA-B2-F
10-10
September, 2015
10
Single Battery Box (Connect to CN4)
Servo Drive
CN2 Connector
Single battery
box for
absolute type
encoder
Incremental type
encoder cable
ASDBCAEN0003,
ASDBCAEN0005,
ASDBCAEN1003,
ASDBCAEN1005
CN4
*2
*1
*3
Motor
Battery Box Cable IW
Note:
This is the wiring diagram of connecting to a single battery box, which is not drawn to scale. For
different models of AC servo drive and motors, the connection cables may differ.
*1 Make sure the battery box is firmly fixed.
*2 Connect to the power based on single battery box. See descriptions below:
1
2
Pin No
Terminal Symbol
Connector Cable
1
BAT+ Red
2 BAT-
Black
*3 Definition of CN4 connector:
Please follow the instructions below when conduct wiring. Wrong wiring might result in explosion.
Pin No
Terminal Symbol
1
BAT
2 BAT-
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...