ASDA-B2-F Panel Display and Operation
September, 2015
4-11
4
4.4.2 JOG Mode
When it is in Parameter Mode, select P4-05 and follow the setting method below for JOG
operation.
1.
Press the SET Key to display the speed of JOG. The default value is 20 r/min.
2.
Press the UP or DOWN Key to adjust the desired speed of JOG. It is adjusted to 100 r/min
in the example.
3.
Press the SET Key to display JOG and enter JOG mode.
4.
When it is in JOG Mode, press the UP or DOWN Key to enable the servo motor in forward
or reverse direction. The servo motor stops running as soon as the user stops pressing the
key. JOG operation is working only when it is Servo ON.
JOG Mode
Display JOG speed.
Its default value is 20 r/min.
SET
Adjust to 100 r/min.
Display JOG and enter JOG Mode.
Press Up / Down Key to adjust JOG speed.
P(CCW) N(CW)
MODE
Exit