ASDA-B2-F Panel Display and Operation
September, 2015
4-3
4
4.2 Parameter Setting Procedure
Switching the mode:
1. If no alarm occurs, the Alarm Mode will be skipped.
2. When new alarm occurs, it will switch to Alarm Mode in any
condition.
3. When switching to the other mode, if no key is being selected
within 20 seconds, it will return to Alarm Mode automatically.
(Please refer to Chapter 9 for detailed alarm description.)
Parameter
Mode
Monitoring
Mode
Alarm Mode
Power On
MODE
MODE
MODE
Please refer to Chapter 7 for parameters
Operating in each mode:
Monitoring mode
Monitoring
Mode
‧‧‧‧
Switch High- / Low-digit
Switch Hex. / Dec. format
SHIFT
SET
1. Pressing Keys can select monitoring
variables. (Please refer to section 4.3.5 for
further detail.)
2. Users can directly enter the code of
monitoring variables via P0-02. (please
refer to Chapter 7 for detailed description.)