Trial Operation and Tuning ASDA-B2-F
5-18
September, 2015
5
5.5.7 Tuning Mode and Parameters
Tuning mode
P2-32
Auto-set
parameters
User-defined parameters
Inertia adjustment
Manual mode
0 (default)
N/A
P1-37(Inertia ratio of the motor)
P2-00 (Position control gain)
P2-04 (Speed control gain)
P2-06(Speed integral
compensation)
P2-25(Low-pass filter of
resonance suppression)
P2-26 (Anti-interference gain)
The value remains
Auto mode
(continuous
estimation)
1
P1-37
P2-00
P2-04
P2-06
P2-25
P2-26
P2-49
P2-31 Frequency response of
speed loop setting in auto mode
(response level)
Continuous tuning
(update the inertia
every 30 minutes)
Semi-auto mode
(non-continuous
estimation)
2
P1-37
P2-00
P2-04
P2-06
P2-25
P2-26
P2-49
P2-31 Frequency response of
speed loop setting in semi-auto
mode (response level)
Non-continuous
tuning (stop
updating the
inertia after
operating for a
while)
When switching mode from auto mode 1 to manual mode 0, the value of P2-00, P2-04, P2-06,
P2-25, P2-26 and P2-49 will be modified to the one in auto mode.
When switching mode from semi-auto mode 2 to manual mode 0, the value of P2-00, P2-04,
P2-06, P2-25, P2-26 and P2-49 will be modified to the one in semi-auto mode.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...