Parameters ASDA-B2-F
7-58
September, 2015
7
P4-16
COF2
Current Detector (V2 Phase) Offset Adjustment
Address: 0420H
0421H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: Factory default
Control
Mode:
ALL
Unit: -
Range: 0 ~ 32767
Format: DEC
Data Size: 16-bit
Settings:
Manually adjust the hardware offset. The adjustment function needs to be enabled by the setting of
parameter P2-08. It is not suggested to adjust the auxiliary adjustment. This parameter cannot be
reset.
P4-17
COF3
Current Detector (W1 Phase) Offset Adjustment
Address: 0422H
0423H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: Factory default
Control
Mode:
ALL
Unit: -
Range: 0 ~ 32767
Format: DEC
Data Size: 16-bit
Settings:
Manually adjust the hardware offset. The adjustment function needs to be enabled by the setting of
parameter P2-08. It is not suggested to adjust the auxiliary adjustment. This parameter cannot be
reset.
P4-18
COF4
Current Detector (W2 Phase) Offset Adjustment
Address: 0424H
0425H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: Factory default
Control
Mode:
ALL
Unit: -
Range: 0 ~ 32767
Format: DEC
Data Size: 16-bit
Settings:
Manually adjust the hardware offset. The adjustment function needs to be enabled by the setting of
parameter P2-08. It is not suggested to adjust the auxiliary adjustment. This parameter cannot be
reset.
P4-19
TIGB
IGBT NTC Adjustment Detection Level (cannot
reset)
Address: 0426H
0427H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: Factory default
Control
Mode:
ALL
Unit: -
Range: 1 ~ 4
Format: DEC
Data Size: 16-bit
Settings:
Please cool down the drive to 25°C when adjusting.
P4-20~P4-23
Reserved
P4-24
LVL
Level of Under Voltage Error
Address: 0430H
0431H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: 160
Control
Mode:
ALL
Unit: V (rms)
Range: 140 ~ 190
Format: DEC
Data Size: 16-bit
Settings:
When the voltage of DC BUS is lower than P4-24*
2
, the under voltage error occurs.
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...