RTU Mode:
Command Message (Master):
Response Message (Slave):
Slave Address
01H
Slave Address
01H
Function 03H
Function 03H
Start Data Address
02H (High)
Data Number
(in byte)
04H
00H (Low)
Data Number
(in word)
00H
Content of Start Data
Address 0200H
00H (High)
02H
B1H
(Low)
CRC Check Low
C5H (Low)
Content of Second Data
Address 0201H
1FH (High)
CRC Check High
B3H (High)
40H (Low)
CRC Check Low
A3H (Low)
CRC Check High
D4H (High)
Note:
Before and after transmission in RTU mode, 10 ms of silent interval is needed.
Example 2: function code 06H, writing single word:
The master issues command to the 1
st
slave and writes data 0064H to address 0200H. The slave
sends response message to the master after writing is completed.
The calculation of LRC and
CRC will be described in the following section.
ASCII Mode:
Command Message (Master):
Response Message (Slave):
Start
‘
:
’
Start
‘
:
’
Slave Address
‘0’
Slave Address
‘0’
‘1’
‘1’
Function
‘0’
Function
‘0’
‘6’
‘6’
Start Data Address
‘0’
Start Data Address
‘0’
‘2’
‘2'
‘0’
‘0’
‘0’
‘0’
Data Content
‘0’
Data Content
‘0’
‘0’
‘0’
‘6’
‘6’
‘4’
‘4’
LRC Check
‘9’
LRC Check
‘9’
‘3’
‘3’
End 1
(0DH)(CR)
End 1
(0DH)(CR)
End 0
(0AH)(LF)
End 0
(0AH)(LF)
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...