Troubleshooting ASDA-B2-F
9-14
September, 2015
9
AL235
PR command overflows
Conduct homing to clear this alarm
Causes
Checking Method
Corrective Actions
PR command overflows
Incremental Type:
Continuous operation in one direction in
PR mode causes position feedback
register (FB_PUU) overflows. Thus, the
coordinate system cannot reflect the
correct position. If issuing the absolute
positioning command at this moment,
the error will occur.
Absolute Type:
If issuing the absolute positioning
command in the following situations, this
error will occur:
1. Feedback position register
(FB_PUU) overflows.
2. When P1-01.Z is modified, homing
has not been completed yet.
3. When electronic gear ratio (P1-44,
P1-45) is modified, homing has not
been completed yet.
4. Function of returning to the original
point is triggered and homing has
not completed yet.
5. AL060 and AL062 occur.
Conduct homing
AL245
PR positioning is over time
N/A
Causes
Checking Method
Corrective Actions
PR positioning is over time.
N/A
If this alarm occurs, please directly
send the servo drive back to Delta
without making any modification.
AL283
Forward software limit
Issue alarm reset to clear this alarm
Causes
Checking Method
Corrective Actions
Forward software limit
Forward software limit is determined by
position command, not the actual
feedback position. That is because the
command always arrives first and then
the feedback. When the protection
function is activated, the actual position
might not exceed the limit yet.
Therefore, setting an appropriate
decelerating time could satisfy the
demand. Please refer to the description
of P5-03.
Issue alarm reset
AL285
Reverse software limit
Issue alarm reset to clear this alarm
Causes
Checking Method
Corrective Actions
Reverse software limit
Reverse software limit is determined by
position command, not the actual
feedback position. That is because the
command always arrives first and then
the feedback. When the protection
function is activated, the actual position
might not exceed the limit yet.
Therefore, setting an appropriate
decelerating time could satisfy the
demand. Please refer to the description
of P5-03.
Issue alarm reset
Summary of Contents for ASD-B2-0121-F
Page 3: ...September 2015 This page is intentionally left blank...
Page 9: ...VI September 2015 This page is intentionally left blank...
Page 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Page 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Page 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Page 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Page 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Page 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...